MPS-XXS wire rope sensor, also known as rope crack meter, crack displacement sensor, rope encoder, rope ruler, rope displacement sensor, cable encoder, cable displacement sensor, is a linear displacement sensor in the structure of the exquisite integration, fully combined with the advantages of Angle sensor and linear displacement sensor, It has become an excellent sensor with compact structure, long measuring stroke, small installation space and high precision measurement. MPS-XXS cable ruler series products have A great choice of space, travel from 100mm to 1000mm, with analog current signal mA: 4-20mA, analog voltage signal V1:0-5V, V2:0-10V and pulse signal P: A, B, Z phase digital output, RS485 digital signal output. Meet large stroke, high precision signal requirements.
Product discription/Technical Parameter
Electric Specifications: | |
Stroke Length(mm) | (100mm~1200mm) |
Output Signal | 0~5VDC or 0~10VDC |
Linearity | ± 0.3%FS(normal standard); ± 0.1%FS(precision) |
Repeatability | ± 0.02%FS |
Resolution | Essentially Infinite |
Wire Measurement | Diameter 0.8mm SUS304 with fluorin-coated,Breaking load at 16kg |
Sensor Type | Wire-Winding potentiometer |
Starting Force | ≤600g |
Max Measuring Speed (back and forth) | 500mm/sec |
Weight | ≤600g |
Mechanic Specifications: | |
Voltage Supply | 0~24VDC for 0-5V output; 12-24VDC for 0-10V output |
Current Supply | Max 10mA |
Data Settings | please see the manual |
Enviroment Specifications: | |
Working Temperature | 0℃~+70℃ |
Storage Temperature | -20℃~+80℃ |
Vibration | 10Hz to 2000Hz |
Ingress Protection | IP65 |
Electric Specifications of Current Wire sensor: | |
Stroke Length(mm) | (0mm~1200mm) |
Output Signal | 4-20mA (3 wires)(2 wires) |
Linearity | ± 0.3%FS(normal standard); ± 0.1%FS(precision) |
Repeatability | ± 0.02%FS |
Resolution | Essentially Infinite |
Wire Measurement | Diameter 0.8mm, SUS304, fluorin-coated |
Sensor Type | Wire-Winding potentiometer |
Starting Force | ≤600g |
Max Measuring Speed (back and forth) | 500mm/sec |
Weight | ≤600g |
Mechanic Specifications of Current Wire sensor: | |
Voltage Supply | 12-24V dc(3wires);15-36V dc(2wires) |
Current Supply | Max 25mA |
Data Settings | please see the manual |
Enviroment Specifications of Current Wire sensor: | |
Working Temperature | 0℃~+70℃ |
Storage Temperature | -20℃~+80℃ |
Vibration | 10Hz to 2000Hz |
Ingress Protection | IP65 |
Electric Specifications: | |
Detection Method | Incremental |
Output Wave | Square Wave |
Stroke Length(mm) | (50mm~1200mm) |
Resolution(mm/Pulse) | 1, 0.5, 0.2, 0.1, 0.04 |
Accuracy | ± 0.05%FS |
Output Phase | AB phase or ABZ phase |
Circuit Character | voltage type, current type, push-pull type,line driver type |
Working Voltage | DC12-24V,DC5Vfixed |
Current Consumption | ≤30mA |
Output Capacity | Sync. Current: 20mA; Residual Voltage: 0.5V or less |
Max Response | 300kHz~500kHz |
Phase Difference | A, B phase difference 90℃±45℃ (T/4±T/8),Z phaseT±T/2 |
Waveform Rise/Fall | 2us or less |
Mechanic Specifications: | |
Wire Measurement | Diameter:0.8mm;SUS304 with fluorin-coated;Breaking load:16kg |
Starting Torque (at 25℃) | Max. 400g |
Max. Travel Speed | 1000mm/sec |
Vibration | 10g (10±1500Hz) |
Polarity Protection | Against Reverse Protection(not with 5V) |
Impact Force | 20g per 11ms |
Weight | <450g |
Starting Force | Max. 700g |
Enviroment Specifications: | |
Working Temperature | 0℃~+70℃ |
Storage Temperature | -20℃~+80℃ |
Working Life | >1×106 cycles |
Ingress Protection | IP65 |
Installation Size (mm)
Wire rope sensor installation notes:
1. Use the two fixing screw holes at the bottom to directly install or add protection or other mechanical use according to the needs of the site and the installation space facilities of the machine.
2. stainless steel cable installation, should pay attention to the horizontal Angle, that is, try to make the cable from the outlet to the moving part of the mechanism, in the work of horizontal sliding.
3. keep a small Angle (allowable deviation +/-3°) to ensure measurement accuracy and cable life.
The steel cable body is made of stainless steel and coated with fluorine layer, do not allow it to be hurt by external force, burn, impact and other improper things: excessive dust, debris accumulation or enough to damage the cable stored in the internal pulley or outlet will cause the cable damage, leading to the failure of operation.
4. Do not use your hand or other products to pull out the steel cable and let it bounce back immediately before it is installed on the workbench or fixed. This will cause the cable to break, damage the body structure and human body.
5. Instantaneous acceleration of reciprocating motion of MPS-S and MPS-M series products shall not exceed 1 m/s; Instantaneous acceleration of reciprocating motion of MPS-L and MPS-L-P series products shall not exceed 0.5 m/s; This action will cause the cable fracture, the company does not assume the responsibility beyond this scope.
6. if used in non-linear movement of the mechanism, please install appropriate pulley operation.
7. if used in bad environment or special occasions, please install the protection mechanism.
Application field of wire rope sensor :
Crack measurement and monitoring, bridge measurement and monitoring, storage location, reservoir dam protection, gate opening control, pressure machinery, paper machinery, textile machinery, sheet metal machinery, packaging machinery, printing machinery, level control instrument, construction machinery, industrial robot, injection machine, woodworking