MR50 magnetic grid ruler is a magnetic grid measurement system, in which MR Is the reading head and MS is the magnetic ruler, and they work according to the principle of magnetic induction. When the MR Reading head moves in a straight line in the magnetic field space of the MS ruler, the reading head will output the position pulse conforming to the standard in real time according to the displacement related to the movement. This product is mainly used in woodworking, stone processing, sawing, metal cutting, textile, printing, packaging, plastic processing, automation system, cutting equipment, electronic assembly equipment, measuring/testing equipment, etc. MR50 magnetic grid ruler has the following advantages: non-contact, high-speed measurement; High resolution; Built-in LED status indicator; Strong anti-fouling and anti-oil ability; Simple installation mode;
MR50 magnetic grid ruler is divided into magnetic strip mounting type and aluminum base mounting type. It is suitable for large measuring range and can be selected according to the site installation environment.
MR50 slider type magnetic gate scale technical specifications: | |
| |
Resolution | 5μm |
Power Supply | 5 ~ 30V DC |
Output Signal | A / B / Z |
Precision(20℃) | ±50μm/m |
Repeatability Precision | Max. ±1 Unit resolution(one-way) |
Measuring Range | Customized |
Installation Gap | Max. 2.5mm |
Move Speed | Max. 25m/s |
No-load Current | Max. 30mA |
output current | Max. 50mA(Each signal) |
operating temperature | -20℃ ~ +85℃ |
Protection | IP68(IEC60529:2001) |
Linear Expansivity | ~ 17 × 10-6/K |
Frequency | 1.25MHZ |
AB signal Number of 1mm pulses | 50 PCS (each 0.02mm,1 pulse) |
The number of pulses per 5mm of Z signal | A pulse |
Anti-interference(EMC) | Electrostatic discharge(ESD: EN61000-4-2); |
Radio-frequency(EN61000-4-3, EN61000-4-6); |
Electrical fast transient(EFT: EN61000-4-4); |
Surge(EN61000-4-5); |
Power frequency magnetic field(EN61000-4-8); |
MR50 slider magnetic gate ruler is based on the principle of magnetic induction. When the reading head moves in a straight line in the magnetic field space of the magnetic scale, the reading head will output the position pulse conforming to the standard in real time according to the relevant displacement of the motion. This product is mainly used for woodworking, stone processing, sawing, metal cutting, textile, printing, packaging, plastic processing, automation system, cutting equipment, electronic assembly equipment, measuring/testing equipment, etc. Product advantages: non-contact, high-speed measurement; High resolution; Built-in LED status indicator; Strong resistance to pollution and oil; Easy installation. |
|
MR50 slider magnetic gate ruler signal output: |
Wiring definition |
+AVCC Red |
OV Black |
A Yellow |
B White |
Z Green |
Sequence diagram
The Z signal has a pulse every 5 millimeters
The Z signal is the correction signal