■ 0.2 level accuracy, the measurement and control speed can be set 10 times or 40 times per second. The display range is -1999 ~ 9999.
■ Double four-digit digital tube display (main display + second display), where the second display can display engineering quantity units, alarm values and other information.
■ Universal input, selectable by setting
■ Optional 1-4 alarm output. Includes 7 kinds of basic alarm methods: upper limit of measured value, lower limit of measured value, upper limit of deviation, lower limit of deviation, upper limit of deviation absolute value, lower limit of deviation absolute value, fault alarm and standby upper limit, lower limit of standby, upper limit of standby deviation, lower limit of standby deviation the way. (Standby alarm mode: refers to no alarm when the measured value is in the output interval when the meter is powered on. When the measured value enters the non-output interval, a standby condition is established, and then the alarm is normal.)
■ 10-segment polyline correction function
■ 1 point external digital input for clearing
■ Peak and bottom value acquisition function.
■ Optional communication and transmission.
Note①: A size instrument
When 1-point digital input is selected, the meter's transmission output and communication functions can only be selected one by one.
Note②: B size instrument
l When 1-point digital input is selected, the meter's transmission output and communication functions can only be selected one by one.
l Note③: C size instrument
l When selecting external power supply, the meter's 1-point digital input, transmission output, and communication functions can only be selected one by one (at this time, the communication only supports RS485)
l When 1-point digital input is selected, the meter's external power supply output, transmission output, and communication functions can only be selected one by one (at this time, the communication only supports RS485)
l When T3R or T4 is selected as the alarm, the external power supply cannot be selected; the transmission output and communication can only be selected from two alternatives, and the communication can only be selected from the RS485 mode (that is, S2 Note④: D size instrument
l When selecting external power supply, the meter's 1-point digital input, transmission output, and communication functions can only be selected one by one (at this time, the communication only supports RS485)
l When 1-point digital input is selected, the meter's external power supply output, transmission output, and communication functions can only be selected one by one (at this time, the communication only supports RS485)
l When T3 is selected as the alarm, external power supply cannot be selected; the transmission output and communication can only be selected from two alternatives, and the communication can only be selected by RS485 (that is, S2).
When selecting 1-point alarm output, only one-point digital input, transmission output, and communication can be selected.
l When 2 points alarm output is selected, it does not support digital input, transmission output and communication Note ⑤: E size instrument
l When selecting 1-point alarm output, only one-point digital input, transmission output, and communication can be selected.
When 2-point alarm output is selected, it does not support digital input, transmission output, and communication