Digital Display Instrument
Product Name:Single channel XSK display controller digital display meter
Product Summary:

It can be connected with our displacement sensor to display the corresponding displacement data. It is widely used in measurement and control of food, chemical, metallurgy, steel, refrigeration and many other industries. Challenge the limits of more application environments and feel more convenient.

Download:
Global Online Advisory
  • Product Overview
  • Technical Parameters
  • Size selection

■ 0.2 level accuracy, the measurement and control speed can be set 10 times or 40 times per second. The display range is -1999 ~ 9999.

■ Double four-digit digital tube display (main display + second display), where the second display can display engineering quantity units, alarm values and other information.

■ Universal input, selectable by setting

■ Optional 1-4 alarm output. Includes 7 kinds of basic alarm methods: upper limit of measured value, lower limit of measured value, upper limit of deviation, lower limit of deviation, upper limit of deviation absolute value, lower limit of deviation absolute value, fault alarm and standby upper limit, lower limit of standby, upper limit of standby deviation, lower limit of standby deviation the way. (Standby alarm mode: refers to no alarm when the measured value is in the output interval when the meter is powered on. When the measured value enters the non-output interval, a standby condition is established, and then the alarm is normal.)

■ 10-segment polyline correction function

■ 1 point external digital input for clearing

■ Peak and bottom value acquisition function.

■ Optional communication and transmission.

Note①: A size instrument

 When 1-point digital input is selected, the meter's transmission output and communication functions can only be selected one by one.

Note②: B size instrument

l  When 1-point digital input is selected, the meter's transmission output and communication functions can only be selected one by one.

l Note③: C size instrument

l  When selecting external power supply, the meter's 1-point digital input, transmission output, and communication functions can only be selected one by one (at this time, the communication only supports RS485)

l When 1-point digital input is selected, the meter's external power supply output, transmission output, and communication functions can only be selected one by one (at this time, the communication only supports RS485)

l When T3R or T4 is selected as the alarm, the external power supply cannot be selected; the transmission output and communication can only be selected from two alternatives, and the communication can only be selected from the RS485 mode (that is, S2                                                                                                                               Note④: D size instrument

l  When selecting external power supply, the meter's 1-point digital input, transmission output, and communication functions can only be selected one by one (at this time, the communication only supports RS485)

l When 1-point digital input is selected, the meter's external power supply output, transmission output, and communication functions can only be selected one by one (at this time, the communication only supports RS485)

l When T3 is selected as the alarm, external power supply cannot be selected; the transmission output and communication can only be selected from two alternatives, and the communication can only be selected by RS485 (that is, S2).

 When selecting 1-point alarm output, only one-point digital input, transmission output, and communication can be selected.

l When 2 points alarm output is selected, it does not support digital input, transmission output and communication                                                                                                                                                                   Note ⑤: E size instrument

l When selecting 1-point alarm output, only one-point digital input, transmission output, and communication can be selected.

When 2-point alarm output is selected, it does not support digital input, transmission output, and communication

内容

代码说明

 

 

XSK-

Analog universal input, 0.2 level display accuracy; 10 or 40 times of measurement and control speed can be set

 

外形尺寸

AH

160×80×125 Horizontal               Hole Size:152×76        (注①)

 

 

AS

80×160×125 Vertical               Hole Size:152×76        (注①)

 

 

B

96×96×76                      Hole Size:92×92         (注②)

 

 

CH

96×48×82 Horizontal                 Hole Size:92×45         (注③)

 

 

CS

48×96×82 Vertical                Hole Size:92×45         (注③)

 

 

D

72×72×75                      Hole Size:68×68         (注④)

 

 

E

48×48×88 Panel loading                 Hole Size:45.5×45.5     (注⑤)

 

Panel specifications

 

Dual 4-digit LED display

 

Alarm (option) (250V AC / 3A, resistive load)

A

T1~T4

1 ~ 4 points alarm relay output, all are normally open + normally closed dual contacts

 

 

 

O1~O4

1 ~ 4 points OC gate output (voltage should be less than 40V DC, current should be less than 40mA)

 

 

B

T1~T2

1 ~ 2 points alarm relay output, all are normally open + normally closed dual contacts

 

 

 

T3~T4

3 ~ 4 points alarm relay output, all are single normally open contacts

 

 

 

O1~O4

1 ~ 4 points OC gate output (voltage should be less than 40V DC, current should be less than 40mA)

 

 

C

T1~T2

1 ~ 2 points alarm relay output, all are normally open + normally closed dual contacts

 

 

 

T3

3-point alarm relay output, all single normally open contacts

 

 

 

T3R

The three-point alarm relay output is a normally open + normally closed double contact.

 

 

 

T4

4 points alarm relay output, the first 3 points are single normally open contacts, and the 4th point is normally open + normally closed double contacts.

 

 

 

 O1~O4

1 ~ 4 points OC gate output (voltage should be less than 40V DC, current should be less than 40mA)

 

 

D

T1~T2

1 ~ 2 points alarm relay output, 1 point normally open + normally closed double contact; 1 point normally open contact

 

 

 

T3

3 points alarm relay output, 1 point is normally open + normally closed double contact, the other 2 points are single normally open contact

 

 

 

 O1~O3

1 ~ 3 points OC gate output (voltage should be less than 40V DC, current should be less than 40mA)

 

 

E

T1~T2

1 ~ 2 points alarm relay output, all are single normally open contacts

 

 

 

O1~O2

1-2 points OC gate output (voltage should be less than 40V DC, current should be less than 40mA)

 

Contact input (optional)

K

1 point external digital input for clearing

 

Transmission (option) (resolution: 1/3000; load capacity 600Ω)

A1

Current Output(4-20)mA、(0-20)mA、(0-10)mA

 

 

A2

Voltage Output(0-5)V、(1-5)V

 

 

A3

Voltage Output(0-10)V

 

 

A4

Voltage Output(-5V~+5V)

 

 

A5

Voltage Output(-10V~+10V)

 

External power supply (option)

B1

24V±5%  Under 50mA

 

 

B2

12V±5%  Under 50mA

 

 

B3

10V±5%  Under 50mA

 

Communication (option) (The communication protocol can be selected through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

RS232 interface (AH, AS, B size only)

 

 

S2

RS485interface

 

Power Specifications

V0

100-240 V AC 50/60 Hz

 

 

V1

10-24V AC 50/60 Hz;10-24V DC

 

Installation method

—AP

Panel loading      (E size only)

 