Technical parameter
Resistance output type:
Stroke Length(mm) | (100mm~1300mm) |
Output Signal | Resistance (Potentiometer) |
Linearity | ± 0.25%FS(normal standard); ± 0.1%FS(precision) |
Repeatability | ± 0.02%FS |
Resolution | Essentially Infinite |
Wire Measurement | Diameter 0.8mm SUS304 with fluorin-coated,Breaking load at 16kg |
Sensor Type | Wire-Winding potentiometer |
Starting Force | ≤600g |
Max Measuring Speed (back and forth) | 500mm/sec |
Weight | ≤600g |
Mechanic Specifications of Resistance Wire sensor: |
Input Resistance | 5ΚΩ ± 10%FS(normal); ±5%FS(precision) |
Rated Power (Watts) | 1W at 70℃(500mm); 2W at 70℃(1000mm) |
Recommended Input Voltage | 12-24VDC |
Enviroment Specifications of Resistance Wire sensor: |
Working Temperature | 0℃~+70℃ |
Storage Temperature | -20℃~+80℃ |
Vibration | 10Hz to 2000Hz |
Ingress Protection | IP65 |
Voltage output type:
Electrical Parameter |
Stroke Length(mm) | (100mm~1300mm) |
Output Signal | 0~5VDC or 0~10VDC |
Linearity | ± 0.25%FS(normal standard); ± 0.1%FS(precision) |
Repeatability | ± 0.02%FS |
Resolution | Essentially Infinite |
Wire Measurement | Diameter 0.8mm SUS304 with fluorin-coated,Breaking load at 16kg |
Sensor Type | Wire-Winding potentiometer |
Starting Force | ≤600g |
Max Measuring Speed (back and forth) | 500mm/sec |
Weight | ≤600g |
Mechanic Specifications of Resistance Wire sensor: |
Voltage Supply | 0~24VDC for 0-5V output; 12-24VDC for 0-10V output |
Current Supply | Max 10mA |
Data Settings | please see the manual |
Enviroment Specifications of Resistance Wire sensor: |
Working Temperature | 0℃~+70℃ |
Storage Temperature | -20℃~+80℃ |
Vibration | 10Hz to 2000Hz |
Ingress Protection | IP65 |
Current output type:
Stroke Length(mm) | (100mm~1300mm) |
Output Signal | 4-20mA (3 wires)(2 wires) |
Linearity | ± 0.25%FS(normal standard); ± 0.1%FS(precision) |
Repeatability | ± 0.02%FS |
Resolution | Essentially Infinite |
Wire Measurement | Diameter 0.8mm, SUS304, fluorin-coated |
Sensor Type | Wire-Winding potentiometer |
Starting Force | ≤600g |
Max Measuring Speed (back and forth) | 500mm/sec |
Weight | ≤600g |
Mechanic Specifications of Resistance Wire sensor: |
Voltage Supply | 12-24V dc(3wires);15-36V dc(2wires) |
Current Supply | Max 25mA |
Data Settings | please see the manual |
Enviroment Specifications of Resistance Wire sensor: |
Working Temperature | 0℃~+70℃ |
Storage Temperature | -20℃~+80℃ |
Vibration | 10Hz to 2000Hz |
Ingress Protection | IP65 |
Storage position location, reservoir dam protection, gate opening control, pressure machinery, paper machinery, textile machinery, sheet metal machinery, packaging machinery, printing machinery, level control instrument, construction machinery, industrial robots, injection machines, woodworking machinery, elevators, air compressor/hydraulic press, height of machine, x-y axis and other length displacement, Measurement and position control of liquid level. |
Installation dimension
Model Selection
Output type:
Resistance output type (potentiometer) : 5kΩ, 10KΩ
Voltage output type: V1:0-5V, V2:0-10V
Current output type: 4-20MA (two-wire, three-wire)
Pulse output type: P: A B Z phase
Digital signal (external/built-in) : RS485
Precautions:
1. The use of the bottom two fixed magnets, according to the site and machine installation space facilities need, directly adsorbed in the installation place or other mechanical use.
2. Stainless steel cable adsorption, pay attention to the horizontal Angle, that is, as far as possible to make the cable from the outlet to the moving part of the mechanism, the horizontal slide during work.
3. Keep a small Angle (allowable deviation +/-3°) to ensure measurement accuracy and cable life.
The steel cable body is stainless steel and coated with fluorine layer, do not let it be hurt by external forces, burn, impact and other improper things: excessive dust, debris accumulation or enough to damage the steel cable stored in the internal pulley or wire outlet will cause damage to the steel cable, resulting in failure of operation.
4. Not installed in the workbench or in front of a fixed seat, do not use your hand or other products to pull out the steel cable and let it bounce back instantly. This will cause the cable to break, damage the body structure and human body safe.
5. The instantaneous acceleration of the reciprocating motion of MPS-S and MPS-M series products shall not exceed 1 m/s; The instantaneous acceleration of the reciprocating motion of MPS-L and MPS-L-P series products shall not exceed 0.5 m/s; This will cause the cable to break, and the company does not assume responsibility beyond this scope.
6. If used in non-linear movement of the mechanism, please install appropriate pulley operation.
7. If used in bad environment or special occasions, please install your own protection mechanism.
Application:
Storage location, reservoir dam protection, gate opening control, pressure machinery, paper making machinery, textile machinery, sheet metal machinery, packaging machinery, printing machinery, level control instrument, construction machinery, industrial robots, injection machines, woodworking machinery, elevators, air compressors/hydraulic presses, height machines, X-Y axis and other length displacement, Liquid level and other related dimensional measurement and position control.